SMT feeder is used for a long time, there will be accuracy error, it needs to be calibrated to ensure that smt feeder work more smoothly and more efficient, the following describes the process of smt feeder calibration.
1.Choose a feeder with best chip-placement ratio, install the Calibration Ruler on this feeder, then place feeder to calibration equipment’s position table.
2.Adjusting the focus-distance H-Axis makes display position centeral on FEEDER component, display show cross cursors in the middle of intersection, make it clear then lock tight, readjust X, Y -Axis makes display position centeral on FEEDER component -eyelet centeral in the middle of intersection, and lock tightly. Then prepare work have complete, please never adjust X, Y, H- Axis again.
3. Remove the FEEDER with Calibration Ruler from calibration equipment, Place the calibration ruler into the feeder need adjust and set up to the Jig position, press Auto/Manual key observe cross cursor centeral whether component cross place to superposition together, if not, please adjust FEEDER bolt-pin to make with display superposition together.Check once wheel gear, and lock screw tightly.
4. How to adjust bolt-pin of the feeder?
b) Adjust X-Axis:: loose screw in Picture D & E, then turn pin in Picture F to adjust X-Axis, after adjustment completed, pls lock the screw in Picture D & E tightly.
More details refer to : Joy Technology Co.,Limited